WINMOD Y200
Overview
Section titled “Overview”Attaches to the Y200 shared memory that WINMOD creates. WINMOD and the gateway must run on the same Windows PC. Platform: Windows only.
Set up and parameters
Section titled “Set up and parameters”| Parameter | Example |
|---|---|
| Shared memory name | Y200 |
| Mutex timeout | 1000 ms |
| Keep-alive | 0 s = off |
| Signal list | C:\Projects\Line1\winmod-signals.txt (optional) |
Couples to WINMOD through its Y200 shared memory. WINMOD creates the memory and CONNECT attaches to it — so WINMOD and the gateway must run on the same Windows PC, and the interface shows an error until WINMOD has started. Addresses are positions in the Y200 memory: MB13.6 (bit), MB7 (byte), MI100 (16-bit integer), MD102 (32-bit integer), MF106 (real). The direction comes from the signal type. Real outputs whose name starts with Joint are converted from radians to degrees.
With a keep-alive set, an interface whose WINMOD has stopped updating its cycle counter for that many seconds reports an error and attaches again. A WINMOD signal list can be browsed, but it carries PLC addresses (%E 0.0), not Y200 positions — complete each imported signal with its MB/MI/MD/MF address.
Create or import signals
Section titled “Create or import signals”- Manually. Enter the position in the Y200 memory:
MB13.6(bit),MB7(byte),MI100(16-bit),MD102(32-bit integer),MF106(real). - Browse. Only from a file. With a signal list (a file on the CONNECT machine, set in the interface settings), Browse lists its rows. The list carries PLC addresses (
%E 0.0), not Y200 positions, so complete each imported signal with itsMB/MI/MD/MFaddress. - File import. The WINMOD signal list above is the file source. There is no separate import dialog.
- From the model. When the model already has its PLC signals, Addresses → Fill from controller… in the signal-mapping section of the CONNECT panel previews matches by exact name against what Browse finds in the signal list and then writes the addresses. Addresses → Import address table… takes a CSV or TSV with
name;address[;dataType[;topic]]rows. New signals take direction and type from the same-named model signal; signals that already exist keep their configured type. See Configuring interfaces. Because the list carries no Y200 positions, the fill cannot supply addresses: enter theMB/MI/MD/MFpositions by hand or through the address table.
How direction, data types and write access are decided is explained in Common concepts and Configuring interfaces.
See also
Section titled “See also”- Common concepts — text signals, direction, write access, tracking signals
- Configuring interfaces — adding signals, direction and write access
- All supported interfaces
- Troubleshooting — connection and signal problems