Mitsubishi MELSEC

Talks MC protocol (SLMP) 3E binary over TCP to MELSEC iQ-R, Q, L and iQ-F controllers.

ParameterExample
Host / Port192.168.3.39 / 5001
Connection timeout5000 ms (default)
CSV fileC:\Projects\Line1\DeviceComments.csv (optional)

CONNECT talks MC protocol (SLMP) 3E binary over TCP — set up a matching open port in the PLC’s Ethernet configuration. Addresses are a device plus a number with an optional value type: M0, X1F, Y10, D100, D200:float, D300:int32, W1A0, T5. Supported devices are X Y M S SM D W R SD T C; X, Y and W are numbered hexadecimal, as in GX Works3, the others decimal. Word devices are 16-bit integers by default; :int32 and :float use two consecutive words, low word first. T and C read the current value.

The direction comes from the signal type: a PLCInput is written to the PLC, a PLCOutput is read. SM and SD are never written. Reads are combined into as few batch requests as the protocol limits allow, and writes send only changed values — registers between two written signals are never touched.

An error code returned by the PLC — for example a device outside the configured range — appears as a signal issue while the connection stays up. With a CSV file set, Browse lists the devices of a GX Works3 device-comment export, with filters per device type.

  • Manually. Enter device and number with an optional value type: M0, X1F, D100, D200:float, D300:int32, W1A0, T5.
  • Browse. Only from a file. With a CSV file set in the interface settings (a path on the CONNECT machine, not uploaded from the browser), Browse lists the devices of a GX Works3 device-comment export, with filters per device type. The controller itself is not browsed.
  • File import. The GX Works3 device-comment CSV above is the file source. There is no separate import dialog.
  • From the model. When the model already has its PLC signals, Addresses → Fill from controller… in the signal-mapping section of the CONNECT panel previews matches by exact name against what Browse finds in the CSV and then writes the addresses. Addresses → Import address table… takes a CSV or TSV with name;address[;dataType[;topic]] rows. New signals take direction and type from the same-named model signal; signals that already exist keep their configured type. See Configuring interfaces.

How direction, data types and write access are decided is explained in Common concepts and Configuring interfaces.