EtherNet/IP

Reads and writes controller tags of Allen-Bradley ControlLogix, CompactLogix, Micro800 and Omron controllers over EtherNet/IP (CIP).

ParameterExample
Gateway10.10.10.10
Path1,0 (backplane, slot 0) — leave empty for Micro800
PLC typeControlLogix, PLC-5, SLC 500, Logix PCCC, Micro800, MicroLogix, Omron
Timeout5000 ms (default) — applies to every tag

Addresses are tag names exactly as they appear in RSLogix or Studio 5000 — MAIN.bStart for a controller-scope tag, Program:MainProgram.MyTag for a program-scope tag. The supported scalar types are BOOL, SINT, INT, DINT and REAL; arrays and UDTs are out of scope.

Discovery reads the controller’s built-in tag list.

  • Manually. Enter the tag name exactly as in RSLogix or Studio 5000: MAIN.bStart for a controller-scope tag, Program:MainProgram.MyTag for a program-scope tag.
  • Browse. Yes. Discovery reads the controller’s built-in tag list.
  • File import. No protocol-specific file import. Use Addresses → Import address table… for a prepared list.
  • From the model. When the model already has its PLC signals, Addresses → Fill from controller… in the signal-mapping section of the CONNECT panel previews matches by exact name against what Browse finds and then writes the addresses. Addresses → Import address table… takes a CSV or TSV with name;address[;dataType[;topic]] rows. New signals take direction and type from the same-named model signal; signals that already exist keep their configured type. See Configuring interfaces.

How direction, data types and write access are decided is explained in Common concepts and Configuring interfaces.