Skip to content

Stäubli CS8/CS9

Beta

Reads a Stäubli CS8 or CS9 controller through its built-in SOAP server. Beta; all signals are read-only.

ParameterDefaultMeaning
Address127.0.0.1Controller IP
Port0SOAP port; 0 selects it automatically (851 on a physical controller)
Username / PasswordEmptyController login for the SOAP server
AxisCount60–6 joints published as axis1 … axisN
RobotIndex0Robot on the controller whose joints are read
TimeoutMs1500 msTimeout for connect and read calls

Couples to a Stäubli CS8 or CS9 controller through its built-in SOAP server. The poll interval is the interface’s update cycle. The login is stored like every other interface password.

AddressDirectionMeaning
axis<N>ReadJoint N in degrees
io:<name>ReadA physical IO by its controller name: digital IOs as Boolean, analog IOs as float
status:runningReadTrue while a VAL 3 application runs

Every Stäubli signal is read by realvirtual; the interface writes nothing to the controller, also with write access on. Power and error state and VAL 3 variables are not available.

  • Manually. Enter axis<N>, io:<name> (the controller’s IO name) or status:running.
  • Browse. No browse: enter addresses by hand.
  • File import. No protocol-specific file import.
  • From the model. Use Addresses → Import address table… in the signal-mapping section of the CONNECT panel: a CSV or TSV with name;address[;dataType[;topic]] rows, where the name is the model’s signal name. New signals take direction and type from the same-named model signal; signals that already exist keep their configured type. Fill from controller… has nothing to match, because this protocol cannot be browsed. See Configuring interfaces.

How direction, data types and write access are decided is explained in Common concepts and Configuring interfaces.