Skip to content

ABB RobotStudio

Publishes a SIMIT-layout shared memory that RobotStudio’s SIMIT connection attaches to. RobotStudio and the gateway must run on the same PC. Platform: Windows only.

CONNECT publishes a SIMIT-layout shared memory that RobotStudio’s SIMIT connection attaches to. Windows shared memory requires RobotStudio and the gateway to run on the same PC, as in a typical RobotStudio virtual commissioning setup.

Addresses are the signal names RobotStudio shows in its SIMIT signal list. Joint values named Joint* arrive in radians and are exposed in degrees.

  • Manually. Enter the signal names RobotStudio shows in its SIMIT signal list. Joint values named Joint* arrive in radians and are exposed in degrees.
  • Browse. No browse: enter addresses by hand.
  • File import. No RobotStudio-specific file import.
  • From the model. Use Addresses → Import address table… in the signal-mapping section of the CONNECT panel: a CSV or TSV with name;address[;dataType[;topic]] rows, where the name is the model’s signal name. New signals take direction and type from the same-named model signal; signals that already exist keep their configured type. Fill from controller… has nothing to match, because this protocol cannot be browsed. See Configuring interfaces.

How direction, data types and write access are decided is explained in Common concepts and Configuring interfaces.