Signal Test Generator
Overview
Section titled “Overview”The Signal Test Generator automatically generates cyclic test values for all PLCInput signals on its parent interface. It discovers Bool, Float, and Int input signals and applies test patterns: sine waves for floats, on/off toggling for bools, and incrementing counters for ints.
Attach it to any interface GameObject to simulate signal activity without a real PLC connection. This is useful for testing interface communication, verifying signal routing, and demonstrating data exchange in demo scenes.
- Select the interface GameObject that contains your PLC signals as children
- Add the Signal Test Generator component (
Tools > realvirtual > Interfaces > Signal Test Generator) - Press Play — all PLCInput signals will start generating test values automatically
The component discovers signals at startup. If you add or remove signals at runtime, click Refresh Signals to re-scan.
Properties
Section titled “Properties”Test Settings
Section titled “Test Settings”| Property | Description |
|---|---|
| Enable Testing | Enable or disable test signal generation |
| Update Interval | Time in seconds between signal value updates |
| Sine Amplitude | Amplitude of the sine wave for float signals |
| Sine Offset | Center offset of the sine wave for float signals |
| Sine Frequency | Frequency of the sine wave in Hz |
| Toggle Interval | Time in seconds between bool signal toggles |
| Int Increment | Increment value per update cycle for int signals |
| Int Max | Maximum value before the int counter resets to zero |
Status
Section titled “Status”| Property | Description |
|---|---|
| Cycle Count | Number of update cycles completed since play started |
Test Patterns
Section titled “Test Patterns”Float Signals (Sine Wave)
Section titled “Float Signals (Sine Wave)”Each PLCInputFloat signal follows a sine wave: Offset + Amplitude * sin(2pi * Frequency * time + phase). Multiple float signals get different phase offsets so they don’t move in sync.
Bool Signals (Toggle)
Section titled “Bool Signals (Toggle)”PLCInputBool signals toggle between true and false at the configured toggle interval. Even-indexed and odd-indexed signals toggle on opposite phases for visual variety.
Int Signals (Counter)
Section titled “Int Signals (Counter)”PLCInputInt signals increment by the configured step each update cycle and wrap around at the maximum value. Multiple int signals get different offsets.
Common Use Cases
Section titled “Common Use Cases”- Interface demo scenes — Show live signal exchange without requiring a PLC
- WebSocket testing — Verify server/client signal transmission with changing values
- UI development — Generate varying signals for testing HMI displays and dashboards
- Integration testing — Simulate signal activity for automated test scenarios